SKILL 未评级 已上架

basement-dampness-doctor

--- name: basement-dampness-doctor description: "Use when a basement or crawl space smells musty, shows mold, efflorescence, or wet spots — or when sizing a dehumidifier. Separates condensation from liquid-water intrusion using dew-point physics (deep-soil wall temperature model), ranks the 10 classic moisture sources, sizes dehumidifier capacity in pints/day, and analyzes humidity logs." version: 1.0.0 author: Denis Voronin license: MIT tags: [home, basement, moisture, mold, dehumidifier, dew-point, diagnostics] --- # Basement Dampness Doctor ## Overview Every damp basement gets one of two wrong treatments: a dehumidifier bought for a *water problem*, or foundation waterproofing sold for an *air problem*. The physics that separates them is simple and checkable: **moisture condenses on any surface colder than the air's dew point**. In summer, basement walls sitting against 13–17°C deep soil chill the air below its dew point — mold on organic surfaces with a dusty-white *absence* of stains on the concrete = condensation. Efflorescence (white salt crystals), staining in vertical streaks, or puddles = **liquid water moving through/along the foundation** — and a dehumidifier will not fix that. This skill computes dew point (Magnus formula), estimates the wall-surface temperature from a deep-soil seasonal lag model, renders a CONDENSATION vs LIQUID verdict, ranks the classic sources (downspouts, grading, window wells, dryer venting...), and sizes dehumidifier capacity honestly (AHAM pints/day by area × dampness class), plus a humidity-log analyzer. ## When to Use - Musty smell, mold spots, peeling paint, "sweating" walls or floor in a basement/crawl space - Deciding between a dehumidifier, a fan, and calling a waterproofing contractor - Sizing/buying a dehumidifier (how many pints? drain vs bucket? energy cost?) - Reviewing a contractor's "you need $12k of interior French drains" quote — the source ranking usually finds the $200 fix first - Don't use for: active flooding (water rising), burst pipes, sewer backup — those are emergency-shutoff problems. ## Quick Start ```bash # 1. Why are my walls wet? (summer classic: humid air + cold walls) python3 scripts/dampdoctor.py analyze --air-t 22 --rh 70 --soil-t 14 \ --wall-t 16 --area 800 --ceiling 2.3 --season summer # 2. What size dehumidifier do I need? python3 scripts/dampdoctor.py dehumidifier --area 800 --class wet --energy-rate 0.34 # 3. Is my existing unit keeping up? (bucket math from measured fill rate) python3 scripts/dampdoctor.py dehumidifier --area 800 --class damp \ --measured-liters-day 6.5 # 4. Rank the moisture sources / crack the case python3 scripts/dampdoctor.py sources --grading negative --downspouts 0.5 \ --gutters clogged --dryer-vent inside --sump none --wall-signs efflorescence # 5. Analyze a humidity log (CSV: date,RH,Temp) python3 scripts/dampdoctor.py log --csv basement_log.csv --target 50 ``` ## The Two-Problem Decision Table | Observation | Condensation (air problem) | Liquid water (ground problem) | |---|---|---| | Wall marks | uniform dust/damp film, mold on organic items, paint peeling in sheets | efflorescence salt lines, streaks from cracks, tide marks, puddles | | Seasonality | worst in humid summer, gone in winter | worst during/after rain or snowmelt, any season | | Floor | damp film, condensate on cold-water tank/pipes | standing water at low point, wet around wall-floor joint | | Fix | dehumidifier + air sealing + stop interior moisture sources | downspouts/grading OUTSIDE, seal cracks, drain tile if hydrostatic | ## Dehumidifier Sizing (AHAM/Energy Star table, 27°C/60% RH test) | Area (m²) | Moderately damp (60–70% RH) | Very damp (70–80%) | Wet (80–100% / seepage) | |---|---|---|---| | 50 | 10 L/day (21 pt) | 12 L (25 pt) | 14 L (30 pt) | | 100 | 14 L (30 pt) | 17 L (35 pt) | 20 L (40 pt) | | 150 | 18 L (37 pt) | 21 L (44 pt) | 25 L (50 pt) | | 250 | 25 L (50 pt) | 30 L (60 pt) | 34 L (70 pt) | | 350+ | 32 L (65 pt) | 38 L (80 pt) | 44 L (90 pt) | Rules: buy the class ×1.2 if the space is open to a humid stairwell; a unit that runs constantly at max is undersized; drain-hose mode beats buckets for anything >12 L/day; Energy Star units ≈ 1.6 L/kWh. ## Common Pitfalls 1. **Dehumidifier for a liquid-water problem.** Pulling 20 L/day from a room fed by a downspout dumping at the foundation just runs the meter — fix the water path first. 2. **Closing the basement "to keep humid air out" in summer.** Summer air at 30°C/60% RH holds more moisture than the basement's 18°C air — ventilating with warm humid air *increases* condensation. Keep it closed + dehumidify. 3. **Efflorescence scrubbed with bleach and called mold.** White crystalline powder = salts left by water passing through concrete = liquid path = outside fix. 4. **Sizing by floor area only.** A wet 30 m² crawl space with an open stairwell needs more capacity than a sealed 100 m² basement — use the class column and the ×1.2 openness factor. 5. **Dryer venting or unsealed sump ignored.** One dryer load = 2–4 L of water into the air if vented inside; an unsealed sump lid is a moisture pump. The `sources` audit prices these. ## Verification Checklist - [ ] Dew point vs wall temperature comparison shown with the verdict (not vibes) - [ ] Wall-sign reading done (efflorescence/mold/tide marks) before any purchase - [ ] Source ranking ordered cheap-first (downspout extensions before drain tile) - [ ] Dehumidifier pints/day from the table × openness factor, with drain recommendation - [ ] If verdict = LIQUID: no dehumidifier recommended as the primary fix ## Example Session ``` $ python3 scripts/dampdoctor.py analyze --air-t 22 --rh 70 --soil-t 14 \ --wall-t 16 --area 800 --ceiling 2.3 --season summer BASEMENT MOISTURE ANALYSIS ══════════════════════════════════════════════════════ Air: 22.0°C @ 70% RH → dew point 16.4°C Deep-soil estimate: 14.0°C | measured wall: 16.0°C → Wall temp (16.0) vs dew point (16.4): wall is BELOW dew point by 0.4°C VERDICT: CONDENSATION LIKELY — expect moisture film/mold on the coldest surfaces (corners, north wall, cold-water tank). Relative risk rises fast: every extra 1°C of cooling or +5% RH widens the gap. Suggested dehumidifier target: 50% RH → extract to dew point ≤ ~11°C. Dehumidifier class for 74 m² (799 ft²), 'damp': ~17 L/day (35 pt) ×1.2 open = 21 L/day class. ```

模型生成摘要(rules/v1 · 2026-11-18 01:35):---
这是模型对公开材料的总结,不是官方声明,请以原链内容为准。

存档时间线

版本存档时间内容哈希内容
v12026-11-18 01:07cc669e1a 可取

版本索引永久保留;内容副本只保留最新 1 份,更早版本仅留索引与哈希(存档时间线的证据链不会因此断裂)。

下载存档内容副本

纠错与举报(发现条目失效、署名有误或涉及侵权?)
提交举报 / 纠错

侵权举报经核验成立后,我们会即时下线该条目并删除已存的内容副本。